117
Installation and Maintenance
Service Manual
GWH24AGD-K6DNA1A/O
3. Remove top panel
1. Remove handle
2. Remove valve cover
Remove the screw xing the handle and then
remove the handle.
Remove the screw xing the valve cover and
then remove the valve cover.
Remove the screws xing the top panel and
then remove the top panel.
Procedure
Step
screw
screw
top panel
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.