35
Installation and Maintenance
Service Manual
8.3 Installation Dimension Diagram
Use suitable instruments for the refrigerant R410A.
● Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
The installation must be done by trained and qualied service personnel with reliability according to this manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guidedby trained and qualied person.
Ensure that the recommende dspace is left around the appliance.
24/28K
18K
30cm or above
Space to the wall
30cm or above
(Air inlet side)
50cm or above
Space to the cover
30cm or above
Space to the wall
30cm or above
Space to the wall
200cm or above
(Air outlet side)
200cm or above
(Air outlet side)
30cm or above
Space to the wall
30cm or above
(Air inlet side)
50cm or above
Space to the cover