89
Installation and Maintenance
Service Manual
Step Ps rocedure
13. Remove
PFC induction
14. Remove 4-way valve assy and suction pipe sub-assy
15. Remove liquid container
PFC induction
4-way valve assy
suction pipe sub-assy
liquid container
Remove the screw connecting the PFC induction
and middle isolation sheet, and then remove the
PFC induction
Unsolder the welding joint connecting the 4-way
valve assy with compressor suction and discharge
port, the valve with the outlet pipe of condenser.
Then lift the 4-way valve assy to remove it.
(NOTE: Discharge the refrigerant completely before
unsoldering.) Unsolder the welding joint connecting
the suction pipe sub-assy with compressor and liquid
container, and then remove the suction pipe sub-assy.
Remove the screws connecting the isolation plate
sub-assy and the liquid container, and then lift the
liquid container to remove it.