Artful
Disassemble Axial Flow Fan
Operating Procedures / Photos
Nut
Axial Flow
Loosen the fastening nut fixing the axial flow fan with
Fan
a spanner ,and then take out the nut,spring gasket
and flap gasket in turn.
Disassemble Motor and Motor Support
Unscrew the 4 screws fixing the motor to take out
the motor,and then unscrew the 2 screws fixing the
motor support to take it out. Motor Support
Screws
Screws
Disassemble Four-way Valve
Unscrew the fastening nut of the four-way valve coil
and remove the coil. Wrap the four-way valve with
wet cotton and unsolder the 4 weld spots connecting
the four-way valve to take it out. (Note:Refrigerant
should be discharged firstly.)
Welding process should be as quick as possible and
keep wrapping cotton wet all the time. Be sure not to
burn out the lead-out wire of compressor.
Four-way valve
Four-way
valve coil
Weld spots