Hydro Box
16
(1) Installation diagram of hydro box connected with water tank:
Fig.4.10
Notes:
Hydro box is only equipped with lower temperature sensor and water tank is equipped
with upper temperature sensor.
Water temperature sensor is introduced to the hydro box from water tank temperature
sensor port 1 to connect with the upper water temperature sensor.
Lower water temperature sensor connects with the lower water temperature sensor
position of water tank from hydro box.
Upper water temperature sensor adopts air connection to connect with temperature
sensor port 1 of water tank.
If adopts the water tank with single temperature sensor, you only need to connect the
upper temperature sensor of water tank with the temperature sensor port of water tank.