Test if there is a fault on the loop cable
1 Disconnect booth loop cable and guide cable (if any)
from the robot mower station. Don’t forget this – your
robot mower station and/or the MS6812 may get
damaged.
2 Connect the red and black cables on the sender
to each of the loop cable like on the picture below.
(which one on each end of loop wire doesn´t matter).
3 Put the sender in “CONT” mode.
There is contact and no fault on the cable if the CONT
lamp lights.
There is a fault if the CONT lamp is not lightning.
Make sure no cables are
conected to charging
station before you connect
the signal cable tracker!