Maintenance
Inspect and clean all parts, replace if necessary.
Shut off cold and hot water supply!
I. Battery
Almost depleted battery is displayed by flashing control light.
1. Push on cleaning clip (L), see Fig. [9].
2. Unscrew screw (M) with 2.5mm allen wrench and pull off
body (N).
3. Pull off protection sleeve (O) and remove battery (P), check
contacts, clean and replace if necessary.
Assemble in reverse order.
II. Solenoid valve
1. Proceed as for maintenance of battery, points 1 to 3.
2. Remove screw (R1) and remove battery holder (R),
see Fig. [10].
3. Detach plug-in connector (S) and remove solenoid valve (T)
by turning clockwise using a 5mm allen key, see Fig. [11].
4. Remove filter (U).
Observe installation position!
Assemble in reverse order.
III. Filter and non-return valve
1. Unscrew connection hose and loosen adapter (B), see
Fig. [12].
2. Unmount filter (C).
Assemble in reverse order.
IV. Unscrew and clean aerator (42 832), see fold-out
page I.
Assemble in reverse order.
V. Mixing spindle
1. Loosen faucet from connections.
2. Unmount faucet from basin.
Disassembling as described in chapter „Setting temperature
limiter“, see Figs. [5] to [7].
3. Pull out mixing spindle (H, I), see Fig. [13].
Assemble in reverse order.
Screw (W) must fit to groove (H1, I1) of mixing
spindle (H, I).
Replacement parts, see fold-out page I ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
Problem / Cause / Remedy
Problem Cause Remedy
Water does not flow Water supply interrupted
Filter before solenoid valve is clogged
Solenoid valve defective
Plug connectors of solenoid valve without
contact
Battery depleted
- Open stop valves, service valves
- Clean, see maintenance solenoid valve
- Replace, see maintenance solenoid valve
- Plug together plug connectors
- Replace, see maintenance electronic battery
Control light flashes Battery almost depleted - Replace, see maintenance electronic battery
Water flows
continuously
Solenoid valve defective - Replace, see maintenance solenoid valve
Water flows
inadvertently
Detect area for the local conditions too
largely adjusted
False signal initiation by object within the
area of the sensor technology
- Reduce range with remote control (special
accessory, ref No. 36 206)
- Mount base (special accessory, ref No. 36 210)
Quantity of water too
small
Filters, aerator are dirty
Service valves not fully opened
Water supply throttled
- Replace, see maintenance filter (III) and aerator (IV)
- Fully open stop valves, service valves
- Check supply pipes, open service valves
faucet set up not
correct
See point „Quantity of water too small“
Mixing spindle calcified
Temperature limiter not correct setted
- Clean, see maintenance mixing spindle
- Setting, see description