SPF 5000 ES Service manual
Internal Inverter component over
100°C
Check whether the air flow of
the unit is blocked or whether
the ambient temperature is
too high.
The battery voltage is too high.
Check if spec and quantity of
batteries are meet
requirements.
Output abnormal (Inverter
voltage below than 190Vac or is
higher than 260Vac)
1. Reduce the connected
load.
2. Return to repair center
Internal components may be
failed.
1. Restart the inverter again.
2. If the problem still exists,
please return to repair center.
1. Check if battery wires are
connected well.
2. If the problem still exists,
please return to repair center.
1. Check whether the AC
output connects to the Grid.
2. Check whether the output
voltage setting in program 8
of all the Inverters in parallel
are the same.
3. Check whether the current
sharing cables are
connected well in the same
parallel phases.
4. Check whether all the
neutral wires of each unit in a
parallel system are
connected together.
5. If the problem still exists,
please return to repair center.
1. Check whether the parallel
communication cables are
connected well.
2. If the problem still exists,
please return to repair center.