EasyManua.ls Logo

Grundfos ALLDOS KM 251 - Filling Gear Oil; Checking the Oil Level; Cleaning the Ball Check Valve

Grundfos ALLDOS KM 251
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KM 251 en
46 15.720148-V1.0
6. Only close the deaeration screw (2u) when the separating agent stops flowing. (after
approx. 5 - 10 min)
Note
Once filled with separating agent and after a few operating hours, especially if the
pressure of the manometer is increasing, deaerate again.
Filling quantity of paraffin oil for dosing pumps with a double diaphragm (per dosing head)
Ordering data for double diaphragm filling components
9.7.5 Filling gear oil
Caution
Risk of leaking and damage caused by oil loss! For each oil change, a new flat gas-
ket (1b) must be used!
Check that the lock screw (B) is tightened.
1. Unscrew and remove the aeration screw and oil-level gauge (F).
2. Set the stroke adjustment button (L) to “0”.
3. Slowly add the hydraulic oil through the aeration screw opening (F), until the oil rea-
ches the mark on the oil-level gauge.
4. Wait 30 minutes.
5. Run the pump for approx. 5 minutes with a stroke adjustment of 0%.
6. Run the pump for approx. 10 minutes with a stroke adjustment of 40%.
9.7.6 Checking the oil level.
7. Switch off pump, check the oil level and add oil if necessary.
8. Fit the aeration screw and oil-level gauge (F) back on.
Caution
Following initial start-up and after each time the diaphragm is changed, tighten the
fixing screws on the dosing head:
After approximately 6 - 10 working hours or two days, tighten the dosing head
screws crosswise using a torque wrench.
Torque:
9.7.7 Cleaning the ball check valve
Note
Only clean the ball check after a diaphragm breakage!
Pump Type Filling quantity in ml
KM 251 4
Order No. Description
555-410 Filling components, set with paraffin oil, throw-away syringe and hose parts
8 - 10 Nm for KM 251 / 10 bar
10 - 12 Nm for KM 251 / 16 bar
13 - 15 Nm for KM 251 / 25 bar

Table of Contents

Related product manuals