Suction Lift:
Highpressurewaterfromthedrivepipepassesthroughtheventuriandpulls
waterfromthewellintotheejector,andthenpushesituptothepump.This
allowsustopushwateruptothepumpfromdepthsgreaterthan25feet,or
toboosttheoutputfromashallowwellpumptohigherpressures.
Handbook
Applications
DRIVE
PIPE
SUCTION
PIPE
VENTURI
NOZZLE
INLET
Rain Water Harvesting:
Reduce,reuse,andrecycle.TheThreeR’sofconservation.Rainwaterharvestingisthewaytostorerainwaterforfuture
usesuchasthewateringofagarden.Simplycollectrainwaterfromtheroofofyourhomethroughtheevesintoastorage
container.UsetheMQtopullasuctionlift,usinganoncollapsiblesuctionline,fromthestoragecontainertowateryour
garden.
Pump Selections:
EZ Boost: Constant Pressure at the touch of a button.
TheEZBoostusesthetimetestedtechnologyusedintheSQEconstantpressuresystem(submersibleapplication).The
MSE3motorsarebasedonsolidstateelectronicsandpermanentmagnetrotorswhichaccountforhighmotorefficiencies.
VariablespeedisofferedthoughfrequencycontrolviatheCU301remotestatusbox.TheSystemcanbesettooperateat
anydutypointintherangebetweenminimumandmaximumperformanceofthepump.TheEZBoosthasbuiltinsafeties
inthesolidstateelectronics.Thesmallfootprintofthepumpallowsthesystemtobepositionedeitherverticallyorhorizon-
tallydependingontheneedsoftheapplication.RefertotheEZBoostinstallationvideoonourwebsitewww.grundfos.us
MQ: Maximum Quality Flow Based Pressure Boosting System:
TheMQisacomplete,all-in-oneunit,incorporatingpump,motor,diaphragmtank,pressureandflowsensor,controllerand
checkvalve.Builtinsafetiesensurelonglifeofthepump.Thesesafetiesinclude:dryrunning;excessivetemperature;any
overloadconditions.TheMQisaselfprimingpumpandneedsnoprimingotherthanthatatinstallation.TheMQisaplug-
n-playsystem.
Basic Line: Durable and dependable Basic Line Jets.
Grundfosoffersshallowwell,deepwell,andconvertiblejetpumps.Ourjetsareself-primingcentrifugalpumpssuitablefor
domesticwatersupply,lightagriculture,andindustrialwatertransferapplications.Threemodelsinclude:JPS;JPF;JDF.The
JPSareshallowwelljetswithbuilt-inejectors.TheJPFareconvertiblejetswithdetachableejectorassemblyfordeepwell
applications.TheJDFaredeepwelljetswithseparatedeepwellportforconnectiontoDeepWellejectorkits.
6
Handbook
Accessories
Pressure Tanks:
TanksareprovidedwiththeEZBoostandMQsystems.TheEZBoosthasanexternaltankandtheMQaninternaltank.The
BasicLinehowevermayneedatankdependingonyourapplication.Inordertominimizethenumberofpumpstartsand
stopsinthewatersupplysystem,andtoreduceproblemswithwaterhammerinthepipework,apressuretankshouldbe
installed.
Pressure Switches:
Pressureswitchesareusedtocontrolpumpoperation.Theseswitcheshaveacut-inpressureandacut-outpressuretoturn
thepumponandoffrespectfully.TheEZBoostcomeswithapressuretransducerforconstantpressure.TheMQhasabuilt-
inpressureswitch.BasicLineJetshavethepressureswitchattached.
Valves:
Check valves: TheEZBoostandMQsystemshavebuilt-incheckvalves.WhendoingasuctionliftwiththeMQacheck
valveisrequiredattheinlet.ThischeckvalveisprovidedwitheveryMQ.
Foot Valves:Whenpullingasuctionlift(shallowordeepwell)withtheBasicLineafootvalveisrequired.Thisvalve
isinstalledattheendofthesuctionpipetopreventbackflow.TheMQwillalsobenefitfromtheuseofafootvalve
whendoingsuctionlifts.
Shut off valves:Useshutoffvalvesinthepipingsysteminsuchawaytomakeitpossibletodrainonlythepartofthe
systemthatneedsattentionorrepair.
Flow control valves:Usedinapplicationswhereasetamountofflow(gallonsperminute)arerequired.Anexample
ofthiswouldbeashowerheadoranirrigationsystem.
Pressure reducing valves:Usedinapplicationswheretheincomingwaterpressureexceedsthemaximuminletpres-
sureofthepumpasisthecasewiththeMQandcitywaterpressure.ThePressureReducingValveorPRVisusedinline
afterthecitywatertapandbeforethepumptoensureasetpressure.
Pressure relief valves: Thisvalveisaspringcontrolleddevisethatcanbeadjustedtomeettheneedsofthepumping
system.Usedinapplicationswherehighpressurecanresultindamagetoaccessoriessuchastankswherethereare
maximumpressureratings.
Theory:
Matching consumption and pump capacity:
Selectingtherightpumpisamatterofmatchingwaterconsumptionwithpumpcapacity.Installinganunderor
oversizedpumpshouldbeavoided.Consumptionvariesgreatlydependingonhousingstandardsandlifestyle.Garden
wateringinthesummercanincreaseconsumption.
Pump Selection:
Pumpselectionisbasedonthewaterdemandandthesystemhead.Thewaterdemanddependsonthenumberof
consumersconnectedtothesystem.HeadcaneitherbeexpressedinfeetorPSI.Headreferstostatichead,pressure
head,andfrictionhead.ForassistanceinPumpSelectionrefertotheWebCAPSselectionprogramfoundonthe
Grundfoswebsite.
Piping:
Inanywatersupplysystem,thesizingandchoiceofmaterialsofthepipeworkhasanimpactonthechoiceofpumps
andonthecost.PipingtakesintoaccountthesystemheadasreferredtoinPumpSelection.Staticheadisthedistance
fromthegroundwaterleveltotheuppermosttap.Pressureheadisthesystempressurethecustomerwantstoachieve.
Inmostresidentialapplicationthispressureisapproximately60PSI.Frictionheaddependsonthepipesize,typeand
length.Whencalculatingfrictionlossalwaysremembertoallowfordeteriorationinthepipingschematicasallwater
pipeswilleventuallybecomecoatedwithrust,limedeposits,etc.Flowvelocityinthepipingmustbekeptlowasnoise
canoccurduetoturbulenceinelbowsandvalvesorfromwaterhammer.Fittingapressurereliefvalveinthedischarge
pipingisrecommendedtoprotectthepipingfromover-pressureduetosystemmalfunction.