EasyManua.ls Logo

Grundfos BMS Series - Product Range; 13 Technical Data

Grundfos BMS Series
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cause Remedy
Malfunctioning or stalled BMS hp pump. Check the operation, flow rates and pressures of the BMS hp pump.
13. Technical data
13.1 Product range
13.1.1 BMS hs PM booster system
Pump type
Motor power
P2
[kW (hp)]
Max. speed
[rpm]
Flow rate
[m
3
/h (US
gpm)]
Min. liquid
temperature
[°C (°F)]
Max. liquid temperature
[°C (°F)]
6)
Max. ambient
temperature
[°C (°F)]
Max. inlet
pressure
[bar (psi)]
Corrosive
Non-
aggressive
BMS 18-16 70 (94) 5500 29 (128) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 18-19 70 (94) 5500 29 (128) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 18-22 44 (59) 4500 24 (106) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 18-22 52 (70) 4500 24 (106) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 18-22 70 (94) 5500 27 (119) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 18-22 85 (114) 5500 30 (132) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-11 70 (94) 5500 53 (233) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-14 85 (114) 5500 55 (242) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-23 140 (188) 5500 53 (233) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-26 100 (134) 4500 42 (185) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-26 140 (188) 5500 50 (220) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 30-26 160 (215) 5500 51 (224) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-8 85 (114) 5500 70 (308) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-9 52 (70) 4500 70 (308) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-13 140 (188) 5500 87 (383) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-15 160 (215) 5500 87 (383) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-17 140 (188) 5000 78 (343) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-17 160 (215) 5000 78 (343) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 46-17 180 (241) 5500 85 (374) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 60-9 85 (114) 5000 98 (431) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 60-15 140 (188) 5000 98 (431) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
BMS 60-17 180 (241) 5000 94 (414) 0 (32) 40 (104) 70 (158) 50 (122) 65 (943)
6)
Contact Grundfos in case of higher temperatures.
Note that BMS hs PM pumps are supplied with Grundfos CUE frequency converters.
25