00235 RtcYear 1 year
Year [0; 254] = [year 2000; year 2254]. See section 11.11 Real-time
clock.
00236 GSMSignalLevelActual 1 %
Actual value of GSM signal level.
254 = Signal level not detectable.
255 = GSM network not available.
Note: Only for CIM 250.
00237 GSMSignalLevelAverage 1 %
Average value of GSM signal level.
254 = Signal level not detectable.
255 = GSM network not available.
Note: Only for CIM 250.
00238 IPAddressHI Unscaled
High-order part of IP address (GPRS only).
Note: Only for CIM 250.
00239 IPAddressLO Unscaled
Low-order part of IP address (GPRS only).
Note: Only for CIM 250.
00240 OverflowLevel 0.01 m Level for activation of overflow level alarm.
00241 HighLevel 0.01 m Level for activation of high-level alarm.
00242 AlarmLevel 0.01 m Level for activation of alarm level alarm.
00243 DryRunningLevel 0.01 m Level for activation of dry-running level alarm.
00244 FoamDrainingLevel 0.01 m Level for foam-draining stop.
00245 StartLevelPump1 0.01 m Start level for pump 1.
00246 StopLevelPump1 0.01 m Stop level for pump 1.
00247 StartLevelPump2 0.01 m Start level for pump 2.
00248 StopLevelPump2 0.01 m Stop level for pump 2.
00249 StartLevelPump3 0.01 m Start level for pump 3.
00250 StopLevelPump3 0.01 m Stop level for pump 3.
00251 StartLevelPump4 0.01 m Start level for pump 4.
00252 StopLevelPump4 0.01 m Stop level for pump 4.
00253 StartLevelPump5 0.01 m Start level for pump 5.
00254 StopLevelPump5 0.01 m Stop level for pump 5.
00255 StartLevelPump6 0.01 m Start level for pump 6.
00256 StopLevelPump6 0.01 m Stop level for pump 6.
00257 FirstGroup2Pump enum
First pump in group 2.
0 = -
1 = -
2 = Pump 2
3 = Pump 3
4 = Pump 4
5 = Pump 5
6 = Pump 6.
00258 BatteryVoltage 0.1 V Voltage level on battery.
00259
IOLogic
Bit 0: Output1
Bool
Status of logic output 1.
0 = Off
1 = On.
IOLogic
Bit 1: Output2
Bool
Status of logic output 2.
0 = Off
1 = On.
IOLogic
Bit 2: Output3
Bool
Status of logic output 3.
0 = Off
1 = On.
IOLogic
Bit 3: Output4
Bool
Status of logic output 4.
0 = Off
1 = On.
IOLogic
Bit 4: Output5
Bool
Status of logic output 5.
0 = Off
1 = On.
IOLogic
Bit 5: Output6
Bool
Status of logic output 6.
0 = Off
1 = On.
IOLogic
Bit 6: Output7
Bool
Status of logic output 7.
0 = Off
1 = On.
IOLogic
Bit 7: Output8
Bool
Status of logic output 8.
0 = Off
1 = On.
00260 RandomStartLevelBand 0.01 m Random start level band (first pump only).