3.5 Inlet pipe guidelines
3.5.1 Common guidelines
Avoid air pockets or turbulence in the inlet pipe
Never use reducers in a horizontal inlet pipe as shown in figure below. Instead, use an eccentric reducer as
illustrated in figure below.
Correct Wrong
1
TM073978
Correctly mounted reducer
1
TM073979
Reducers resulting in air pockets and turbulence
Pos. Description
1 This must face downwards
Pos. Description
1 Air pocket
3.5.2 Flooded systems
Closed systems and open systems where the liquid level is above the pump inlet.
Correct
1
2
TM074028
Correctly mounted inlet pipe
Pos. Description
1 Eccentric reducer
2 Pipe sloping down towards pump