RCS User Manual
81
7.3.- Configuration
Using this feature, the user can configure all the parameters that take part in the polling mode. The
window of this feature is different depending on the type of input (IP or RF).
If the selected input is RF, the user must set: locking time, stabilizing time and measuring
time, as well as selecting the channels that the user wants to monitor.
The maximum locking time is the maximum time during wich the RCS will try to lock the signal.
The stabilizing time is the time that the RCS must wait for the measurements to stabilize, once the
signal is locked.
The measuring time is the time during which the RCS makes the measurements and generates the
alarms in each channel. Once the time has elapsed, the RCS tunes to the next channel.
In the channel selection table the user can select the channels he wants to include in the monitoring
Polling.
If the selected input is IP, the user must set the maximum locking time and the measuring
time, as well as select the channels that he or she wants to monitor.