EasyManua.ls Logo

GTO PRO3040-G3 - Page 2

GTO PRO3040-G3
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Power Cable from
the Master Arm
GRNCOM COM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
RECEIVER
ORGBLUEWHTGRN BRN RED
MASTER INPUTS
BLK
MASTER CABLE
CONTROL INPUTS
Step 2
Strip approximately
3
/16" of insulation from each wire of
the opener power cable. Twist each exposed wire tightly
(there are seven [7] wires inside the power cable sheath).
Loosen sealing nut on strain relief hub at bottom of
control box. Insert power cable into control box through
strain relief. Thread approximately 6" of the power cable
into the control box and retighten sealing nut until the
power cable locks into place.
Step 3
Insert the stripped power cable wires into the
appropriate terminals on the MASTER INPUTS
terminal block. The green wire should be inserted
into the GRN terminal, the white wire into WHT,
the blue wire into BLUE, brown wire into BRN, and
the orange wire into the ORG terminal, red wire into
RED, and black wire into BLK.
Tighten the set screws against the end of the wires.
A dab of petroleum jelly on each terminal will help
prevent corrosion.
Correct
Wrong Wrong
Wire
Terminal
Block
Terminal
Block
Terminal
Block
Wire Wire
Connecting Opener Power Cable
Sealing Nut
Hub
Lock Nut
Strain Relief
Step 1
Make sure the control box power switch is in the OFF position.
The ON/OFF Switch is located on the bottom of the control
box. Remove the control box cover and slide the battery into
position with its terminals to the RIGHT (see illustration).
Connect the BLACK battery wire to the NEGATIVE () battery
terminal. Connect the RED battery wire to the POSITIVE (+)
terminal. Pay close attention to the color of the wires. If the wires
are connected incorrectly, the control board will be damaged.
NEVER insert the battery with the terminals to the left.
RED wire to POSITIVE (+) terminal
BLACK wire to NEGATIVE () terminal
RED
BLACK
Operator Power Cable
RECEIVER
25
FUSE
BATT+
BATT-
1 2 3 4
ON DIP
RECEIVER
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
ALM
S2
MASTER INPUTS
SOLAR
or
18 VAC
SLAVE INPUTS
LOCK
GTOAUX
GTO
LOCK
PWR
AUX
RLY
POWER
INPUTS
CONTROL
OUTPUTS
MASTER CABLESLAVE CABLE
CONTROL INPUTS
AUTO CLOSE TIME STALL FORCE
12 V Battery (Included)
Strain Relief
Space for optional
second 12 Volt battery
(see Accessory Catalog)
Battery wires for
optional second battery.