V12 Pet Friendly
Installation Instructions
Walk Test LED
Electronics Module
Front Cover
A
A*
BB
A
A
B*B
Connector Block
Switches
PIR Sensor
(Do not touch)
Declination
Indicator
Note: If internal EOL
resistors in use
connect the loop to
terminals 3 and 7
1 2 3 4 5 6 7
NC
ALARM
12 V
Power
NC
TAMPER
T
E
S
T
+
(loosen only, do not remove)
Cover Screw
Main Lens
PCB
Cable Entry
Sneak Lens
Main Lens
Screws
Off Wall Tamper
Switch
Cover Tamper Switch
Tamper Lever
Lens Module
Base
Pet Alley Mask
PCB
Knockout Holes:
A - Corner mounted
B - Flush mounted
For the off-the-wall tamper to be operational,
screw must be fitted in either A* or B*.
Lens
Module
No. Function
1 LED Enable
2 Pulse Count
3 PIR Gain 1
4 PIR Gain 2
5 HS EOL 1
6 HS EOL 2
FACTORY
DEFAULTS
Enabled
Enabled
7m
7m
Connected
Connected
Disabled
Disabled
10m
10m
Off
Off
OFF
ON
1 2 3 4 5 6
Question and Answer IconNeed help?

Do you have a question about the Guardall V12 Pet Friendly and is the answer not in the manual?

Guardall V12 Pet Friendly Specifications

General IconGeneral
BrandGuardall
ModelV12 Pet Friendly
CategorySecurity System
LanguageEnglish

Summary

Coverage Diagrams

Side View Pet Friendly V12

Diagram showing the side view coverage of the Pet Friendly V12 detector.

Pet tolerant area

Indicates the area within which pets are tolerated by the detector.

Technical Specification

Detector Voltage

Specifies the operating voltage range for the detector.

Current

Details the current consumption in alarm and non-alarm states.

Max Ripple

Specifies the maximum allowable ripple on the power supply.

PIR Coverage Adjustment

Describes the horizontal coverage adjustment.

LED Indication

Explains how the LED is used for indication.

Temperature Range

Specifies the operational temperature limits.

Temperature compensation

Details how the detector compensates for temperature changes.

Alarm Output (NC ALARM)

Specifies the normally closed alarm output contact.

Alarm Period

Specifies the duration of the alarm output signal.

Tamper Output (NC TAMPER)

Specifies the normally closed tamper output contact.

Test Input (TEST)

Describes how to use the test input for activation.

Initial Installation

Avoid False Alarm Sources

Guidelines for avoiding common false alarm triggers like sunlight or drafts.

Preparation and Mounting

Steps for preparing the detector, removing the cover, and selecting mounting.

Wiring

Instructions for running cables and connecting wires to the PCB terminal block.

Detector Settings

Pulse Count

Enabling Pulse Count reduces false alarms by requiring two detections.

PIR Gain

Adjusting PIR gain to decrease detection range from 10x10m to 7x7m.

Checking V12 Coverage

Procedure to verify detector coverage, including LED enable and walk testing.

Diagnostics and Troubleshooting

Periodic Self Test

Detector performs self-tests; failure indicated by dim LED.

Supply Voltage Monitor

Monitors supply voltage; low voltage causes LED to flash.

LED Indications

Details LED behavior for low voltage, alarm, and self-test failures.

Troubleshooting Common Issues

Guides on issues like no LED indication, flashing LED, dim LED, and continuous PIR activity.

Warranty Information

Information on product warranty against defects in workmanship and materials.

Pet Friendly Operation

Operating Principle

Masks lower beams and declines remaining beams to allow pets to move freely.

Lens Adjustment for Pets

Advice on moving the lens towards position A if pets on furniture cause alarms.