Operation &
Maintenance
Manual
Issue:
10
A6ML0066 Euroblast SF Instruction Manual
Date:
05/2019
Page: 31
7.1.2 Viewing and illumination window
* The Euroblast 2 SF cabinet has a different sized window fitted:
Item code
Description
P2PF0014
Euro 2 Antifrost sheet
P2GL0010
Euro 2 Glass
Check that the view of the component to be blasted is not impaired by a scratched
anti frost sheet (P2PF0013*) or glass (P2GL0009*). Replace if necessary.
The window gasket should also be inspected and replaced when worn (R5SL0009).
Check there is enough light entering the
cabinet to work by. If not the illumination
window (P2GL0012) may be scratched.
Replace if necessary.
The rubber gasket (R5SL0000) and the
gasket filler strip (R5SL0002) should
also be inspected and replaced if
necessary.