A6ML0066 Euroblast SF Instruction Manual
Date:
05/2019
Page: 71
If a problem occurs with installation then Guyson International should be contacted to provide support.
If the yellow indicator is visible
where the arrow points to, the
blue reset button needs to be
pressed. If the Dust Collector is
still not functional, readjust the
trip setting up slightly.
If the problem persists, contact
Guyson International.
On both single and three phase motors it
is essential to check that the direction of
rotation matches the arrow attached to
the motor housing. This is best done
visually. If the motor is rotating in the
wrong direction, it will be necessary to
switch off the machine, isolate the
electric supply and reverse the position
of L1 and L2 on single phase machines
or any TWO of the feed wires (L1, L2 or
L3) on three phase machines.