SWEep Subsystem
:SWEep:TYPE {FREQuency|VAC|IAC}
:SWEep:TYPE?
Function It sets or queries the sweep type.
Description
Set parameter
FREQuency | VAC(voltage) |IAC(current)
Set syntax
:SWEep:TYPE FREQuency
Query syntax
:LIST:RETest?
Return
data FREQ | VAC | IAC (Format is in <disc>)
:SWEep:XAXis {LOGarithm|LINear}
:SWEep:XAXis?
Function It sets or queries the XAXIS.
Description
Set parameter
LOGarithm | LINear
Set syntax
:SWEep:XAXis LOGarithm
Query syntax
:SWEep:XAXis?
Return
data LOG | LIN (Format is in <disc>)
:SWEep:XAXis:DATA?
Function It queries the XAXIS data.
Description
Query syntax
:SWEep:XAXis:DATA?
Return da
ta
+1.000000E+03,+1.209960E+05,+2.409920E+05,+3.609880E+05,…+
3.000000E+07(Format is in <NR3>)