LCR-8000 Series User Manual
72
Setting func
Select the combination of parameters to be sweep test.
Func1-16: Z-Deg, Y-Deg, R-X, G-B, Z-Cs, Z-Cp, Z-Ls, Z-Lp, Cs-Rs,
Cp-Rp, Cp-G, Cs-D, Ls-Rs, Lp-Rp, Lp-G, Ls-Q.
FUNC selection If you do not have the desired test parameters, you
can go to the PARA item of TRACE A/B and select the required
test parameters.
1. Press the Measure button to enter
[MEAS DISPLAY] page, and then
press the SWEEP function button on
the right side of the LCD to enter the
[SWEEP DISPLAY] page.
2. Use arrow keys to move the cursor
and select FUNC item on the [SWEEP
DISPLAY] page.
3. Use option key on the right of the LCD screen
to select a function type for this sweep item.