PEL-3000(H) User Manual
54
6. Set the current level parameters using the scroll
wheel and number pad.
For Static mode, set CC A Value and/or CC B
Value.
For Dynamic mode, set Level1 and Level2.
The maximum and minimum current levels
depend on the selected ranges.
7. To add CV mode to CC mode (CC+CV), see
page 60.
8. Set the remaining basic configuration settings
such as the slew rate, and switching function
settings. See page 65 for details.
Display
Mode
CC
I Range
H 8.75A
VRange
L 80V
Function
Static
Configure
0.000
V
0.0000
A
0.00
W
SlewRate 140.00
CC B Value 0.0000
CC A Value 0.0000
LOADRS232
A Value
Fine
01/Oct/2018
mA/uS
A
A
Mode
Current range
Voltage range
Active setting
Current setting A
Current setting B
Basic CC mode configuration is complete. See page 65
for more configuration options.
The current range and voltage range applies to all the
operating modes.