FUNCTION MENU
119
Program chains need not be executed in order.
There are 16 steps to a program.
There are up to 16 programs to a chain.
PROGRAM 1
STEP 01
STEP 02
:
STEP 16
PROGRAM 2
STEP 01
STEP 02
:
STEP 16
PROGRAM 3
STEP 01
STEP 02
:
STEP 16
Setting Overview
A program contains the following settings for each
step:
Memory: the memory location of the load
operation for the selected step (M001-M256).
Run: Designates the run setting for the step
(Auto, Manual, Skip).
On-Time: Sets the run time of the test.
Off-Time: Sets the off time between steps.
P/F-Time: Sets the testing pass/fail delay time
for GoNo Go testing.
Short-Time: Sets the shorting time for the step,
if any.
Timing Diagram
for Single Step
Below is a timing diagram of a single step in a
program.