PSW Series User Manual
84
Analog Connector
Connection
2
12
17
20
21
Master unit
A COM16
OUTPUT ON STATUS21
ALM STATUS20
STATUS COM17
SHUTDOWN12
Slave Unit 1
25 SER SLV IN
20 ALM STATUS
12 SHUTDOWN
2 D COM
24 OUT OFF/ON CONT
2 D COM
24 20 12
17
25
2
16
17 STATUS COM
Series Output
Connection
Master unit
Load
+
-
Slave unit
Steps
4. Remove the output terminal cover
and the protection dummy plug
from the analog control connector.