CONFIGURATION
113
Power On Configuration Settings
CV Control
Sets the constant voltage (CV) control mode
between local and external voltage/resistance
control. For external voltage control, see page
122 (External Voltage Control of Voltage
Output) and page 127 (External Resistance
Control of Voltage Output).
F-90
0= Panel control (local)
1 = External voltage control
2 = External resistance control
(Ext-R 10k = Vo,max)
3 = External resistance control
(Ext-R 10k = 0)
CC Control
Sets the constant current (CC) control mode
between local and external voltage/resistance
control. For details on external voltage control,
see page 125 (External Voltage Control of
Current Output) and 129 (External Resistance
Control of Current Output).
F-91
0= Panel control (local)
1 = External voltage control
2 = External resistance control
(Ext-R 10k = Io,max)
3 = External resistance control
(Ext-R 10k = 0)
Power-ON
Output
Configures the power supply to do one of the
following at startup: keep the output off, turn
the output on, or load a test script.
F-92
0 = OFF at startup
1 = ON at startup
T001 ~ T010 = Run test script TXX