CONFIGURATION
99
Configuration
Configuration of the PSW power supplies is divided into five
different configuration settings: Normal Function,
USB/GPIB/RS232, LAN, Power ON Configuration, Calibration
Settings and System Settings. Power ON Configuration differs from
the other settings in that the settings used with Power ON
Configuration settings can only be set during power up. The other
configuration settings can be changed when the unit is already on.
This prevents some important configuration parameters from being
changed inadvertently. Power On Configuration settings are
numbered F-90 to F-95 and the other configuration settings are
numbered F-00 to F-61, F-71 to F-74 and F-88 to F-89.
Configuration Table
Please use the configuration settings listed below when applying
the configuration settings.
V-I mode slew rate select
0 = CV high speed priority
1 = CC high speed priority
2 = CV slew rate priority
3 = CC slew rate priority
0.01V/s~60.00V/s (PSW 30-XX)
0.1V/s~160.0V/s (PSW 80-XX)
0.1V/s~320.0V/s (PSW 160-XX)
0.1V/s~500.0V/s (PSW 250-XX)
1V/s~1600V/s (PSW 800-XX)
Falling voltage slew rate
0.01V/s~60.00V/s (PSW 30-XX)
0.1V/s~160.0V/s (PSW 80-XX)
0.1V/s~320.0V/s (PSW 160-XX)
0.1V/s~500.0V/s (PSW 250-XX)
1V/s~1600V/s (PSW 800-XX)