14 | Features
AUTOMATIC CHARGER
AL 800
GB
FEATURES
For 2 V, 6 V and 12 V lead batteries (Lead-gel,
leadfleece or lead-acid)
Electronic protection against short-circuits (<
1 min.) and incorrect polarity
Automatic battery maintenance
mode (Automatic refreshing of
the battery after charging)
– Constant charging end voltage
I/U charging characteristic
No charging takes place when
the battery is connected to the
wrong polarity
3 LED status displays: Mains,
charging, wrong polarity
TECHNICAL DATA
Operating voltage:
230 VAC/50 Hz
Charging end voltage: 2.3 V,
6,9 V, 13,8 V max.
Max. charging current 800 mA
for lead batteries 1.2 – 63 Ah
– Protection class: IP20
THE I-U-CHARGING CONCEPT charges the lead-battery with constant
current of 800 mA (0,8A) until the end of charge voltage is reached for the
respective battery. The charger recognises this and switches to constant
current in order to adjust the charging current down (Maintenance charger).
The battery charger is therefore maintained at an ideal level. As a result, the
battery can be plugged into the charger for a longer period of time. This is
the reason why this device is suitable for “over wintering”. The plug charger is
protected against overcharge and short-term short-circuit (<1min.). A protective
circuit avoids charging in case of incorrect poling that could destroy the
battery as well as the charger. Incorrect poling will be indicated by a red
light.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H-Tronic AL800 and is the answer not in the manual?

H-Tronic AL800 Specifications

General IconGeneral
Battery Voltage12 V
Operating ModeAutomatic
Input Voltage230V AC
Output Voltage12V DC
ProtectionShort-circuit, overcharge, reverse polarity
Battery TypeLead Acid, Gel, AGM
Charging Stages3-stage