85
Maximum server operating
temperature
Hardware options
GPU-P100.
GPU-V100-32G.
GPU-V100.
27°C (80.6°F)
Any of the following GPU modules used with 165W (or higher)
processors:
GPU-K80-1.
GPU-M60-1-X.
GPU-P40-X.
30°C (86°F)
Any of the following GPU modules used with less than 165W processors:
GPU-K80-1.
GPU-M60-1-X.
GPU-P40-X.
35°C (95°F)
DCPMMs.
Samsung NVMe drives.
Rear drives.
NVMe SSD PCIe accelerator module.
Rear SATA M.2 SSD.
GPU modules:
{ GPU-P4-X.
{ GPU-M4-1.
{ GPU-T4.
{ GPU-MLU100-D3.
{ GPU-M10-X.
40°C (104°F)
15000 RPM HDDs and four operating fans.
10000 RPM 1.2 TB (or higher) HDDs and four operating fans.
NVMe drives, excluding Samsung NVMe drives.
Ethernet adapter IB-MCX453A-FCAT-56/40Gb-1P or
IB-MCX453A-FCAT-56/40Gb-1P-1.
45°C (113°F) None of the above hardware options or operating conditions exists.
8LFF server with any drive configuration
Use Table 27 to determine the maximum operating temperature of the 8LFF server. A maximum
server operating temperature applies if the server contains any options in its matching hardware
option list.
If a single fan fails, the maximum server operating temperature drops by 5°C (41°F) and cannot
exceed 35°C (95°F).
NOTE:
All maximum server operating temperature values are provided on the basis that the fans are
installed as needed and operating correctly. For more information about fan configurations, see the
guidelines in "Installing fans."