EasyManua.ls Logo

Hach DR/850 - Page 248

Hach DR/850
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
248
REQUIRED REAGENTS
Low Range Nitrate Reagent Set (100 tests)..................................................................24298-00
Includes: (1) 21071-69, (1) 21072-49
Quantity Required
Description Per Test Unit Cat. No.
NitriVer 3 Nitrite Reagent Powder Pillows..............1 pillow ...............100/pkg..........21071-69
NitraVer 6 Nitrate Reagent Powder Pillows ............1 pillow............... 100/pkg..........21072-49
REQUIRED APPARATUS
Cylinder, graduated, mixing, 25 mL............................. 1...........................each............1896-40
Sample Cell, 10-20-25 mL, w/ cap............................... 2.........................6/pkg..........24019-06
OPTIONAL REAGENTS
Description Unit Cat. No.
Bromine Water, 30 g/L...........................................................................29 mL
*
............2211-20
Nitrate Nitrogen Standard Solution, 10.0 mg/L as NO
3
-
-N...................500 mL..............307-49
Nitrate Nitrogen Standard Solution, Voluette ampule,
12 mg/L as NO
3
-
-N, 10 mL................................................................. 16/pkg..........14333-10
Phenol Solution, 30 g/L...........................................................................29 mL............2112-20
Pretreatment Kit, contains: (1) 2112-20, (1) 2211-20.................................each............2268-00
Sodium Hydroxide Standard Solution, 5.0 N ............................ 50 mL* SCDB............2450-26
Sulfuric Acid, ACS..............................................................................500 mL*..............979-49
Water, deionized............................................................................................4 L..............272-56
OPTIONAL APPARATUS
Ampule Breaker..........................................................................................each..........21968-00
Dropper, for 29-mL bottle...........................................................................each............2258-00
Flask, volumetric, Class A, 100 mL ...........................................................each..........14574-42
pH Indicator Paper, 1 to 11 pH .......................................................... 5-roll/pkg..............391-33
pH Meter, sens
ion
1, portable, with electrode..........................................each..........51700-10
Pipet, serological, 2 mL..............................................................................each..............532-36
Pipet, TenSette, 0.1 to 1.0 mL.....................................................................each..........19700-01
Pipet Tips, for 19700-01 TenSette Pipet................................................. 50/pkg..........21856-96
Pipet Tips, for 19700-01 TenSette Pipet ............................................1000/pkg..........21856-28
Pipet, volumetric, Class A, 2.00 mL...........................................................each..........14515-36
Pipet Filler, safety bulb...............................................................................each..........14651-00
Thermometer, –20 to 110 °C.......................................................................each..........26357-02
Nitrate at these levels can also be determined directly using the Nitrate Ion Selective Electrode
(Cat. No. 23488-00).
For Technical Assistance, Price and Ordering
In the U.S.A.—Call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
* Contact Hach for larger sizes
NITRATE, Low Range, continued