306
ORGANIC CARBON, TOTAL, Mid Range, continued
REQUIRED REAGENTS
Total Organic Carbon Direct Method Mid Range
Test ’N Tube Reagent Set ......................................................................50 vials..........28159-45
Includes:
Quantity Required
Description Per Test Unit Cat. No.
Acid Digestion Solution Vials, Mid Range TOC ...................1 ............. 50/pkg
............................. *
Buffer Solution, Sulfate.....................................................0.4 mL .........25 mL..............452-33
Funnel, micro..........................................................................1.................each..........25843-35
Indicator Ampules, Mid/High Range TOC.............................1.............50/pkg....................... *
TOC Persulfate Powder Pillows .............................................1.............50/pkg....................... *
Water, organic-free
**
.........................................................1.0 mL .......500 mL..........26415-49
REQUIRED APPARATUS
DRB 200 Reactor, 110 V, 15 x 16 mm tubes..................................................LTV082.53.40001
DRB 200 Reactor, 220 V, 15 x 16 mm tubes..................................................LTV082.52.40001
Cylinder, graduated, 10-mL....................................................1.................each..............508-38
Flask, Erlenmeyer, 50-mL ......................................................1.................each..............505-41
Magnetic Stirrer, 115 V, 4" x 4"..............................................1.................each..........28812-00
Test Tube Rack .....................................................................1–3...............each..........18641-00
Pipet, TenSette
®
, 0.1 to 1.0 mL..............................................1.................each..........19700-01
Pipet Tips, for 19700-01 TenSette
®
Pipet...............................2............. 50/pkg..........21856-96
Stir Bar, Magnetic...................................................................1.................each..........45315-00
Wipes, Disposable, Kimwipes................................................1...........280/pkg..........20970-00
OPTIONAL REAGENTS
Description Per Test Unit Cat. No.
TOC Standard Solution (KHP Standard, 1000 mg/L C)...........................5/pkg..........27915-05
Potassium Acid Phthalate ......................................................................... 500 g..............315-34
Sulfuric Acid Reagent Solution, 5.25 N......................................100 mL MDB............2449-32
OPTIONAL APPARATUS
Analytical Balance......................................................................................each..........28014-01
DRB 200 Reactor, 110 V, 21 x 16 mm and 4 x 20 mm ..................................LTV082.53.42001
DRB 200 Reactor, 220 V, 21 x 16 mm and 4 x 20 mm ..................................LTV082.52.42001
DRB 200 Reactor, 110 V, 9 x 16 mm and 2 x 20 mm ....................................LTV082.53.30001
DRB 200 Reactor, 220 V, 9 x 16 mm and 2 x 20 mm ....................................LTV082.52.30001
Flask, volumetric, 100-mL..........................................................................each..........14574-42
Pipet, Class A, 10.00-mL............................................................................each..........14515-38
Pipet, Class A, 15.00-mL............................................................................each..........14515-39
Pipet Tips, for 19700-01 TenSette Pipet ............................................1000/pkg..........21856-28
* These items are not sold separately.