Figure 8 Real time screen
Figure 9 Real time screen for sensor with depth
2. Profiler— Select this option to do stream or conduit velocity measurements. The meter shows
prompts when user input is necessary. A percentage of the remaining memory is given in 1%
resolution. Refer to the expanded version of the manual for more information about profiles.
Option Description
Stream This option is used to set up a profile for a stream or flowing channel. Do velocity
measurements to calculate total discharge based on ISO 748 or USGS standards for
Mid-section or Mean-section methods.
Conduit This option is used to set up a profile for a conduit.