Page 15
8837hrd.fm Installation
Section 2 Installation
2.1 Selecting the Installation Site
DANGER
This product is not designed for
hazardous locations where
combustible environments may
exist.
The sampler is designed for outdoor installation and does not require a
secondary enclosure. Stainless steel angle rails are located on the left side
and right underside of the refrigerator cabinet and anchor the sampler to a
concrete pad (expansion bolts not included) or grating.
Follow the simple guidelines below to allow complete drainage of the intake
line and prevent cross-contamination between samples:
• Install the sampler as close to the source as site conditions permit.
• Install the sampler above the sample source, with the intake tubing
sloping downward to the sample source.
• Make sure that the tubing is free of kinks and loops.
2.2 Installing the All Weather Refrigerated Sampler
The sampler can be installed using the optional anchor bracket mounting kit
(Cat. No. 8935).
1. Determine the proper site location for individual permanent installation.
2. Level the sampler using four leveling feet. Raise the sampler by turning
the feet clockwise.
3. Locate screws around base of cabinet. The front and rear screws are
used to mount the anchor brackets to the sampler.
4. Remove one screw from the cabinet. Slide the screw through the slot in
the anchor bracket and tighten halfway.
Note: Install only one bracket at a time. The sampler may become unstable if multiple
screws are removed at once.
5. With screw still loose, allow the anchor to drop down firmly in contact with
mounting surface (floor, concrete, etc.)
6. Assemble the remaining three brackets.
7. Complete installation by securing the anchor brackets to the mounting
surface as required for individual installation.
Note: A customer-supplied
7
/16 bolt or stud is recommended to ensure secure
mounting.