Installation Instructions
Minimum Room Area
Type
LFL
kg/m3
hv
Total Mass Charged/kg
Minimum Room Area/m
2
R32 0.306
4 7 10 15 20 30 50
0.6
0.90
1.08 1.32
1.53
1.87
2.41
1.0
1.51
1.80
2.20
2.54
3.12 4.02
1.8
2.71
3.24
3.97
4.58
5.61 7.24
2.2
3.31 3.96 4.85 5.60
6.86 8.85
m
0.68
1.14
2.05
2.50
It should be stated in the manual that an entire connection pile should be used.
It should be stated in the manual that it is recommended to place the joint of the connection pipes at the
outdoor side, if can’t be at the outdoor side, the side that cannot be reused (not detachable) must be installed
at the indoor side.
When the connection pipe is reused, the horn mouth needs to be reinstalled.
Diameter of the liquid
connecting pipe (mm)
Extra gas amount per meter
after standard length (g)
6/6.35 20g
9/9.52 50g
Notes: The most gas amount should be: initial gas amount + extra gas amount <
permitted gas by safety standard.
R32 Air Conditioner Adding Extra Gas With Longer Pipe Calculator
WARNING!
The area of the room in which R32 refrigerant air conditioner is installed cannot be less than the minimum
area specified in the table below, to avoid potential safety problems due to out-of-limit of refrigerant
concentration inside the room caused by leakage of refrigerant from refrigeration system of the indoor unit.
Once the horn mouth of connecting lines is fastened, it may not be used again (the air tightness may be
affected).
A whole connector wire shall be used for indoor/outdoor unit as required in the operation specification of
installation process and operation instructions.
Installation Precautions
Important Information Regarding The Refrigerant Used
A contains fluorinated greenhouse gases covered by
the Kyoto
Protocol
B factory refrigerant charge of the product: see unit
name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
GWP=global warming potential
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the
atmosphere. Refrigerant type: R32
3
3 GWP* value=675
tCO2=(1+2) x 3 /1000