EasyManua.ls Logo

Haier 1U24RE8ERA - Sensors List

Haier 1U24RE8ERA
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specification
Domestic air conditioner
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type R410a
Refrigerant charge KG 1.45
Maximum allowable distance
between indoor an outdoor
m 25
Maximum allowable level difference m 15
Refrigerant control Capillary
Piping connections
(external diameter)
liquid mm ĭ6.35
gas mm ĭ12.7
drain mm ĭ16
Heat insulation type Both liquid and Gas pipes
Max. piping Length m 15
Max. vertical Difference m 10
Chargeless m 7
Amount of Additional Charge of Refrigerant g/m 20
Intemational Protection degree IP 24
Note: the data are based on the conditions shown in the table below
cooling heating Piping length
Indoor: 27 DB/19 WBćć
Outdoor: 35 DB/24 WBćć
Indoor:20 DBć
Outdoor: 7 DB/6 WBćć
5m
3ˊSensors list
type Description Qty
Ambient sensor Its used for detecti 1edisroodtuofoerutarepmetgn
Defrosting sensor Its used for controlling outdoor defrosting at heating mode 1
1taeh-revofoesacnirosserpmocrofdesustIrosnesgnigrahcseD
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3
8

Other manuals for Haier 1U24RE8ERA

Related product manuals