Service diagnosis
41 Domestic air conditioner
10.3.10 The communication fault between indoor and outdoor
Indoor display
E7
outdoor display
LED1 flash 15 times
Met
hod of
Communication is detected by checking the indoor PCB and the outdoor PCB.
Malfunction
Detection
Malfunction
The outdoor PCB broken leads to communication fault.
D
ecision
The indoor PCB broken leads to communication fault.
Conditions
S
upposed
Co
mmunication wiring disconnected.
Causes
The indoor PCB is broken.
The outdoor PCB is broken.
The Module PCB is broken.
Troubleshooting
* Caution
Be sure to turn off power switch before connect or disconnect connector, or else
p
arts damage may be occurred.