137
Comb.
Combinations
Rated
capacity(kW)
(Nom. heating)
Total heating
capacity(kW)
Total power input
(W)
Total current
(A)@230V
COP
(W/W)
ENERGY
LABEL
SCOP
(W/W)
ENERGY
LABEL
REMARKS
Unit
A
Unit
B
Unit
C
Unit
A
Unit
B
Unit
C
Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Max.
data
Rated
capacity
1x1
2.0 2.30 0.80 2.30 4.00 0.55 0.64 1.40 2.44 2.83 6.21 3.61 A 3.70 A not available
2.5 3.60 0.80 3.60 6.00 0.55 0.98 1.50 2.44 4.35 6.65 3.67 A 3.70 A not available
3.5 4.50 1.00 4.50 6.00 0.55 1.22 1.65 2.44 5.41 7.32 3.69 A 3.70 A not available
4.2 5.40 1.50 5.40 6.00 0.55 1.45 1.90 2.44 6.43 8.43 3.72 A 3.70 A not available
5.0 6.00 1.50 6.00 8.00 0.55 1.60 2.00 2.44 7.10 8.87 3.75 A 3.70 A not available
BI (1x2)
7.1 7.00 1.50 7.00 8.60 0.55 1.84 2.20 2.44 8.16 9.76 3.80 A 3.70 A not available
2.0 2.0 2.30 2.30 2.60 4.60 8.00 0.55 1.25 2.00 2.44 5.55 8.87 3.68 A 3.80 A available
2.0 2.5 2.30 3.60 2.70 5.90 8.50 0.55 1.60 2.00 2.44 7.10 8.87 3.69 A 3.80 A available
2.0 3.5 2.30 4.50 2.70 6.80 8.50 0.55 1.82 2.10 2.44 8.07 9.32 3.74 A 3.80 A available
2.0 4.2 2.27 5.33 2.90 7.60 8.50 0.55 2.06 2.10 2.44 9.14 9.32 3.69 A 3.90 A not available
2.0 5.0 2.11 5.49 2.90 7.60 8.50 0.55 2.05 2.10 2.44 9.09 9.32 3.71 A 3.90 A available
2.5 2.5 3.60 3.60 2.90 7.20 8.50 0.55 1.93 2.10 2.44 8.56 9.32 3.73 A 3.90 A available
2.5 3.5 3.38 4.22 2.90 7.60 8.50 0.55 2.05 2.10 2.44 9.09 9.32 3.71 A 3.90 A available
2.5 4.2 3.04 4.56 2.90 7.60 8.50 0.55 2.06 2.10 2.44 9.14 9.32 3.69 A 3.95 A not available
2.5 5.0 2.85 4.75 2.90 7.60 8.50 0.55 2.05 2.10 2.44 9.09 9.32 3.71 A 3.95 A available
TRI
(1x3)
3.5 3.5 3.75 3.75 2.90 7.50 8.50 0.55 1.93 2.20 2.44 8.54 9.76 3.90 A 3.80 A available
3.5 4.2
3.45 4.15 2.90 7.60 8.50 0.55 2.02 2.20 2.44 8.96 9.76 3.76 A 4.00 A+ not available
3.5 5.0 3.26 4.34 2.90 7.60 8.50 0.55 2.00 2.20 2.44 8.87 9.76 3.80 A 4.00 A+ available
4.2 4.2 3.80 3.80 2.90 7.60 8.50 0.55 2.00 2.20 2.44 8.87 9.76 3.80 A 4.00 A+ not available
2.0 2.0 2.0 2.30 2.30 2.30 2.90 6.90 8.50 0.55 1.85 2.30 2.44 8.21 10.20 3.73 A 4.05 A+ available
2.0 2.0 2.5 2.13 2.13 3.34 2.90 7.60 8.50 0.55 1.98 2.30 2.44 8.78 10.20 3.84 A 4.05 A+ available
2.0 2.0 3.5 1.92 1.92 3.76 2.90 7.60 8.50 0.55 1.96 2.30 2.44 8.70 10.20 3.88 A 4.05 A+ available
2.0 2.0 4.2 1.75 1.75 4.10 2.90 7.60 8.50 0.55 1.95 2.30 2.44 8.65 10.20 3.90 A 4.05 A+ not available
2.0 2.0 5.0 1.65 1.65 4.30 2.90 7.60 8.50 0.55 1.95 2.30 2.44 8.65 10.20 3.90 A 4.05 A+ available
2.0 2.5 2.5 1.84 2.88 2.88 2.90 7.60 8.50 0.55 1.90 2.30 2.44 8.43 10.20 4.00 A 4.08 A+ available
2.0 2.5 3.5 1.68 2.63 3.29 2.90 7.60 8.50 0.55 1.85 2.30 2.44 8.21 10.20 4.11 A 4.08 A+ available
2.0 2.5 4.2 1.55 2.42 3.63 2.90 7.60 8.50 0.55 1.85 2.30 2.44 8.21 10.20 4.11 A 4.08 A+ not available
2.0 2.5 5.0 1.47 2.30 3.83 2.90 7.60 8.50 0.55 1.86 2.30 2.44 8.25 10.20 4.09 A 4.08 A+ available
2.0 3.5 3.5 1.55 3.03 3.03 2.90 7.60 8.50 0.55 1.88 2.30 2.44 8.34 10.20 4.04 A 4.10 A+ available
2.0 3.5 4.2 1.43 2.80 3.36 2.90 7.60 8.50 0.55 1.85 2.30 2.44 8.21 10.20 4.11 A 4.10 A+ not available
2.5 2.5 2.5 2.53 2.53 2.53 2.90 7.60 8.50 0.55 1.81 2.30 2.44 8.03 10.20 4.20 A 4.20 A+ available
2.5 2.5 3.5 2.34 2.34 2.92 2.90 7.60 8.50 0.55 1.84 2.30 2.44 8.16 10.20 4.13 A 4.20 A+ available
2.5 2.5 4.2 2.17 2.17 3.26 2.90 7.60 8.50 0.55 1.84 2.30 2.44 8.16 10.20 4.13 A 4.20 A+ not available
2.5 3.5 3.5 2.17 2.71 2.71 2.90 7.60 8.50 0.55 1.84 2.30 2.44 8.16 10.20 4.13 A 4.20 A+ available
3U70S2SR2FA combination and the data