174
Super Match
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) AD24MS1ERA AD24MS1ERA(D)
AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D) AD28NS1ERA(S) AD36NS1ERA(S)
AD48NS1ERA(S)
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Indoor temperature
Max.
Min.
DB/WB
DB/WB
32/23°C
18/14°C
Outdoor temperature
Max.
Min.
DB/WB
DB/WB
46/24°C
10/6°C
Heating
Indoor temperature
Max.
Min.
DB/WB
DB/WB
27°C
15°C
Outdoor temperature
Max.
Min.
DB/WB
DB/WB
24/18°C
-15°C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualied
person.
3. If the fuse on the indoor PC board is broken please change it with the type of T 6.3A /250VAC(For series
24,28,36,48).
4. The wiring method should be in line with the local wiring standard.
5. The power cable should be:
H05RN-F 3G 4.0mm2 (For series 12,18,24);
The connecting cable should be:
H05RN-F 4G 1.3mm2 (For series 12,18,24,28,36,48)
All the cables shall have got the European authentication certicate. During installation, when the connecting
cables break off, it must be assured that the grouding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be
no less than 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
10. For AD12MS1ERA and AD12MS1ERA(D),AD18MS1ERA,AD18MS1ERA(D), AD24MS2ERA,AD24MS2ERA(D),
AD28MS2ERA(S),AD28MS2ERA(S)(D),we can get the 4 different ESP through adjust the indoor unit PCB SW1-
4 and SW1-5, please refer below:
SW1
Static pressure
(1) (2) (3) (4) (5) (6) (7) (8)
- - - OFF OFF - - - 10 Pa
- - - OFF ON - - - 30 Pa
- - - ON OFF - - - 50 Pa
- - - ON ON - - - 70 Pa
Attention: cut off the power supply to adjust the SW1-4, and SW1-5, or else the operation is invalid.