Super Match
WARNING
For AD48HS1ERA(S) AD60HS1ERA(S)
Safety precautions
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Indoor temperature
Max.
Min.
DB/WB
DB/WB
32/23°C
18/14°C
Outdoor temperature
Max.
Min.
DB/WB
DB/WB
46/24°C
10/6°C
Heating
Indoor temperature
Max.
Min.
DB/WB
DB/WB
27°C
15°C
Outdoor temperature
Max.
Min.
DB/WB
DB/WB
24/18°C
-15°C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualied
person.
3. If the fuse on Pc board is broken, please change it with the type of T 3.15A /250VAc.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided. The connecting cable should be H05RN-F 4G 0.75mm2.
All the cables shall have got the European authentication certicate. During installation, when the connecting
cables break off, it must be assured that the grouding wire is the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be
no less than 3mm.
7. The indoor unit installation height is at least 2.5m.
8. In order to obtain the Unit’s best performances, the fan speed is recommended according to the following
conditions.
Outdoor ambient temp. Operation mode Recommended fan speed
>40°C cooling low
<20°C cooling high
<-5°C heating low
>18°C heating high
Parts and Functions
Indoor unit
Note
All wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions
do not cover all variations for every kind of installation circumstance. Should further information be desired or
should particular problems occur, the matter should be referred to your local distributor.
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION
AND/OR PROPERTY DAMAGE.