330
Super Match
Installation drawings of indoor and outdoor units
1 Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without
connecting the indoor unit in order to add another indoor unit later. Make sure no dirt or moisture gets into either
side of the embedded branch piping.
2. It is impossible to connect the indoor unit for one room only.
Cut thermal insulation pipe to an appropriate
length and wrap it with tape, making sure that no
gap is left in the insulation pipe's cut line.
Wrap the insulation pipe with the nishing tape
from bottom to top.
Installation gure please refers to 4U30HS1ERA.
Attention must be
paid to the rising
up of drain hose
If there is the danger of the unit falling or overturning, x the unit with foundation bolts, or with wire or other means.
If the location does not have good drainage, place the unit on a level mounting base(or a plastic pedestal).
Install the outdoor unit in a level position. Failure to do so may result in water leakage or accumulation.
Arrangement of piping directions
Rear left
Left
Reat right
Right
Below