Electic Control and
Debugging
361
Super Match
Outdoor main PCB 0151800075 dip switch setting
1 2 3 4 5 6 7 8 Decription
ON --- --- --- --- --- --- --- Cooling only
OFF --- --- --- --- --- --- --- Heating pump(default)
--- ON --- --- --- --- --- --- set ON if frost easily
--- OFF --- --- --- --- --- --- set OFF if hard to frost(default)
--- --- ON --- --- --- --- --- Max.running current is 15A
--- --- OFF --- --- --- --- --- Normal control(default)
--- --- --- OFF OFF ON --- --- 3U19
--- --- --- OFF ON OFF --- --- 3U24
--- --- --- OFF ON ON --- --- 4U26
--- --- --- ON OFF ON --- --- 4U30
--- --- --- ON ON OFF --- --- 5U34
--- --- --- ON OFF OFF --- --- 5U45
--- --- --- --- --- --- ON --- temperature correction valid
--- --- --- --- --- --- OFF --- temperature correction null(default)
--- --- --- --- --- --- --- ON Quiet operation valid
--- --- --- --- --- --- --- OFF Quiet opoperationeration vaild(default)
SW7: pre-set dip switch (default : all OFF)
Small service PCB:0151800076 dip switch setting
SW1 denition:
1 2 3 4 Denition
OFF OFF OFF OFF State when out of factory
ON OFF OFF OFF
Compulsory heating: 50Hz, outdoor motor 5-class, standard open angle 200, the
others are normal
OFF ON OFF OFF
Compulsory cooling: 60Hz, outdoor motor 7-class, standard open angle 200, the
others are normal
OFF OFF ON OFF Rated operation
OFF OFF OFF ON Time defrost valid
ON ON ON ON Detection for wrong wiring
4 3 2 1 Outdoor central control address
OFF OFF OFF OFF 1
OFF OFF OFF ON 2
OFF OFF ON OFF 3
OFF OFF ON ON 4
OFF ON OFF OFF 5
OFF ON OFF ON 6
OFF ON ON OFF 7
OFF ON ON ON 8
ON OFF OFF OFF 9
ON OFF OFF ON 10
ON OFF ON OFF 11
ON OFF ON ON 12
ON ON OFF OFF 13
ON ON OFF ON 14
ON ON ON OFF 15
ON ON ON ON 16
SW6: outdoor central control address setting