390
Super Match
AP48~60KS1ERA(S)
LED ash times of
indoor PCB
Remote
receiver
display
Contents of Malfunction
LED4 LED3
0 1 E1 Malfunction of indoor unit ambient temperature sensor
0 2 E2 Malfunction of indoor unit piping temperature sensor
0 4 F8 EEPROM wrong of indoor PCB
0 5 F5 Indoor anti-freezed protection
0 7 E9 Abnormal communication between indo- or and outdoor units
0 8 E8
Abnormal communication between wired controller and indoor
unit
0 9 F4 Protection of overload of heat mode
0 12 E0 Malfunction of drain system
0 13 EF Zero cross sigal wrong
0 14 E10 Be lack of phase failure
0 15 ED Failure of aided coil sensor
0 16 F3 Indoor abnormal mode operation
3 0 E3 Faulty temperature Te
3 2 E3 Faulty temperature Ta
3 1 E3 Faulty temperature Ts
3 3 E3 Faulty temperature Td
6 2 E6 High pressure switch abnormal
6 3 E6 Low pressure switch abnormal
3 6 E6 Low pressure protection(lack of R410A)
2 1 EE Outdoor EEPROM failure
3 2 E9 Communication abnormal between indoor and outdoor
2 3 E5
Protection of over current of compressor among phases/wrong
phases
4 5 E5 Protection of low current of compressor
2 9 F6 Outdoor DCmotor abnormal
2 8 E4 Outdoor discharging temp. sensor abnormal
3 7 F2 4-way valve reverse abnormal in heating mode
2 8 E7 Power source too high/low voltage protection
F7 Other frequency conversion outdoor failures
Note:
1.The outdoor failure can also be indicated by the indoor unit,the checking method as follo- ws: LED4 ash
times stands for tens digit,and LED3 ash times stands for units digit, use this bidigitate gure minus 20,then
will get the outdoor error code.For example,if the outdoor error code is 15,LED4 will ash 3 times rstly,two
seconds later,LED3 will ash 5 times , and four seconds later the process will repeat again.
2.LED4 is a yellow one on the indoor PCB,LED3 is a green one.
3.To get much more details about the out door unit failure,please refer to the outdoor unit trouble shooting list.