Super Match
Item Model AC28ES1ERA(S)/1U28HS1ERA(S)
Function cooling heating
Capacity kW 8.5
2.1-10.0) 9.5(2.2-10.5)
Sensible heat ratio / /
Total power input kW 2.355(0.5-4.2) 2.632(0.5-4.2)
Max. power input W 4200 4200
EER or COP W/W 3.61 3.61
Dehumidifying capacity 10
³×m³/h 3.0
Power cable /
Power source N, V, Hz 1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 10.2(2.2-18.5)/18.5 11.4(2.2-18.5)/18.5
Start Current A 5
Indoor
unit
Unit model (color) AC28ES1ERA(S)
Fan
Type × Number CENTRIFUGALX3
Speed(H-M-L) r/min 1145/1092/956(50Hz,5UF capacity)
Fan motor output/ input power W 60/145
Air-ow(H-M-L) m³/h 1630/1537/1375
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 3
Total Area /
Dimension
External
L×W×H
mm×mm×mm 1298/700/244
Package
L×W×H
mm×mm×mm 1500/790/315
Drainage pipe (material , I.D./O.D.) mm PP 20/25
Controller (O-Optional,S-Standard)
Wired(S) YR-E17(O)/YR-E16A(O)
Infrared(O) YR-HD01(S)
Fresh air hole dimension mm 200
Electricity Heater kW none
Sound power Noise level (H-M-L) dB(A) 64
Sound pressure Noise level (H-M-L) dB(A) 49/45/43
Weight (Net / Shipping) kg / kg 37/47
Piping
Refrigerant
Type / Charge g R410A/2000
Recharge quantity g/m 45
Max. pipe length without
charge refriigerant
m 20
Pipe
Liquid mm 9.52
Gas mm 15.88
Between I.D
&O.D
MAX.Drop m 15
MAX.Piping length m 25
Connection Method ared
Cooling Pdesignc(kW)
8.5KW SEER/CLASS 5.6/A+ QCE(Annual electricity consumption for cooling)kWh
543
Heating
Average Pdesignh(-10
) 7.2KW SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating)kWh
2970
Warmer Pdesignh(2
) 8.3 SCOP/CLASS 5.0/A++ QHE(Annual electricity consumption for heating)kWh
2509
Colder Pdesignh(-22
) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh
/
Tdesignh
-10
Tbivalent
-10
TOL
-15
Elbu:0
Max. cooling
condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature
46
/-
Outdoor temperature
24
/18
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a