• Crimp connection method for wires without terminals
• Crimp connection method for connection wire
• After connection, the wire must be fastened by wire cover. The wire cover shall press on the protection coat of
the connection wire, as shown in right top gure.
Note:When connecting the wiring, conrm the terminal number of indoor and outdoor units carefully.
Incorrect wiring will damage the controller of air conditioner or the unit can not operate.
9.3 Wiring method of outdoor unit:
• Power cord
Remove the Valve cover of the outdoor unit and loosen the wire cover A, then put the live wire, neutral wire and
grounding wire through the wire cover, and connect them to terminal block correspon dingly. After connection,
fasten wire cover to its previous state. Communication wire of indoor unit.
• Loosen wire cover, put the communication wire through the wire cover B, and connect them to terminal block
correspondingly. After connection, fasten wire cover B to its previous state.
Note: Power cord and communication wire are provided by consumers themselves.