46
Item Model 3U68S2SG1FA
Function - Cooling Heating
Rating capacity W 6900 7700
Cooling Pdesign W 6900
Heating Pdesign(-10
℃
) W 5300
Rated power input (indoor + outdoor) W 1720 2200
Rated current input (indoor + outdoor) A 7.55 9.60
EER / COP W/W 3.7 4.2
SEER / SCOP W/W 7.5 4.1
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 8200 9000
Maximum power input (indoor + outdoor) W 3400 3400
Power source - 1PH, 220-240V~, 50/60Hz
Max.Running current (indoor + outdoor) A / A 14.2 14.2
Power facor(under rating power input) - 99% 99%
Starting current A 4
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture - SVB172FNPMC/ MELCOM
Oil charge and type - 600CC/FW68S
Type - Twin Rotary (DC inverter)
Number - 1
Fan
Type × Number - Axial × 1
Speed r/min High 820
Motor output/input power W 80/100
Air-ows (H/M/L) m³/h about 2500
Heat exchanger
Type / Diameter mm TP2M / 7.0
row - 2
Face area m² about 0.52
Dimension
(WxDxH)
External mm 860/308/730
Package mm 1005/423/815
Refrigerant control method - PMVs
Defrosting method - Automatic by reversible cycle
Crankcase heater power W NONE
Noise level
Sound power level dB(A) 67
Sound pressure level dB(A) 54
Weight Net / Shipping kg / kg 53/56