48
Item Model 4U70S2SH1FA
Function - Cooling Heating
Rating capacity W 7100 8400
Cooling Pdesign W 7100
Heating Pdesign(-10
℃
) W 6000
Rated power input (indoor + outdoor) W 1700 2000
Rated current input (indoor + outdoor) A 7.50 8.70
EER / COP W/W 4.4 4.5
SEER / SCOP W/W 7.2 4.2
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 9000 9500
Maximum power input (indoor + outdoor) W 4300 3500
Power source - 1PH, 220-240V~, 50/60Hz
Max.Running current (indoor + outdoor) A / A 18.8 15.2
Power facor(under rating power input) - 99% 99%
Starting current A 5
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture - TVB220FAEMC-L/ MELCOM
Oil charge and type - 870CC/ FW68S
Type - Twin Rotary (DC inverter)
Number - 1
Fan
Type × Number - Axial × 1
Speed r/min High 860
Motor output/input power W 100/125
Air-ows (H/M/L) m³/h about 3500
Heat exchanger
Type / Diameter mm TP2M / 7.0
Row - 2
Face area m² about 0.75
Dimension
(WxDxH)
External mm 948/340/840
Package mm 1040/430/1000
Refrigerant control method - PMVs
Defrosting method - Automatic by reversible cycle
Crankcase heater power W NONE
Noise level
Sound power level dB(A) 70
Sound pressure level dB(A) 56
Weight Net / Shipping kg / kg 76/87