EasyManua.ls Logo

Haier AB25S2SC1FA - Page 52

Haier AB25S2SC1FA
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
Item Model 4U85S2SH1FA
Function - Cooling Heating
Rating capacity W 8400 9500
Cooling Pdesign W 8400
Heating Pdesign(-10
) W 7000
Rated power input (indoor + outdoor) W 2400 2350
Rated current input (indoor + outdoor) A 10.50 10.40
EER / COP W/W 3.8 4.3
SEER / SCOP W/W 7.0 4.3
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 9800 10500
Maximum power input (indoor + outdoor) W 4300 3500
Power source - 1PH, 220-240V~, 50/60Hz
Max.Running current (indoor + outdoor) A / A 18.8 15.2
Power facor(under rating power input) - 99% 99%
Starting current A 5
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture - TVB220FAEMC-L/ MELCOM
Oil charge and type - 870CC/ FW68S
Type - Twin Rotary (DC inverter)
Number - 1
Fan
Type × Number - Axial × 1
Speed r/min High 860
Motor output/input power W 100/125
Air-ows (H/M/L) m³/h about 3500
Heat exchanger
Type / Diameter mm TP2M / 7.0
row - 2
Face area about 0.75
Dimension
(WxDxH)
External mm 948/340/840
Package mm 1040/430/1000
Refrigerant control method - PMVs
Defrosting method - Automatic by reversible cycle
Crankcase heater power W NONE
Noise level
Sound power level dB(A) 70
Sound pressure level dB(A) 56
Weight Net / Shipping kg / kg 76/87

Other manuals for Haier AB25S2SC1FA

Related product manuals