EasyManua.ls Logo

Haier AB422XCBAA - 2.2 Model AU422 XIBAA

Haier AB422XCBAA
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
>a__WcU[S^<[c>a`V[e[a`Wc
——
Cooling Heating
BTU/h
42000 48000
W
12500 14000
W
5600 5600
W
6300 6300
W/W
2.23 2.50
10³×m³/h
//
——
——
N, V, Hz
A / A 26.0 / 30.0 26.0 / 30.0
A
A
Model / Manufacture ——
Oil charge and type ——
Type ——
Number ——
Type × Number ——
Speed r/min
Motor output power W
Air-flows (H/M/L) m³/h
Type / Diameter mm
Total area
Temp. scope
External mm
Package mm
Drainage pipe material, diameter mm
——
——
——
——
W
Noise level H/M/L dB(A)
Weight Net / Shipping kg / kg
Type / Charge g
No need to recharge m
Recharge g/m
Liquid mm
Gas mm
——
Drop between IU &
OU
m
Drop between indoor
units
m
Piping length
m
Total length
m
Item Model AU422XIBAA
Function
Capacity
Capacity
Total power input
Max. power input
EER or COP
Dehumidifying capacity
Power cable
3 × 5.0mm
2
Power source
1, 220~230, 50
Communication cable
8x(0.75~1.25mm
2
)
Running / Max.Running current
Start current (system A / system B)
55.0 / 55.0
Outdoor
Compressor
PG420X3CS-4KU1 / TOSHIBA
Rotary (Fix speed)
2
Fan
Axial × 2
850±50/720±50/500±50
60 × 2
6000/4000/3000
Heat exchanger TP2M / 9.52x0.35
about 1.17
cooling: 43~60 / heating: 6~7
Dimension
(L×W×H)
948×340×1250
1050×440×1375
/
Capillary tube
Defrosting method
Automatic
28*2
Material of reduce noise
XPE
Crankcase heater power
Type of 4-way valve
DPF-6
Refrigerant control method
35
Pipe Φ6.35
Φ12.7
* Long piping length and large drop between the indoor and outdoor unit (which exceeds standard value) will
obviously reduce the capacity.
Connecting method
Flared
Between I.D &O.D <=15m(Outdoor unit above indoor )
<=10m(Outdoor unit below Indoor )
15 (per way)
30 (2 ways)
720 CC (RB68AF/T68/α68TF)
Fuse size (recommended size)
40
5
60/-/-
101/121
Piping
Refrigerant R407C / 2450 × 2
Piping length less than 5 meters in one
way
-9-