128
Super Match
Item Model AD28NS1ERA(S)/1U28GS2ERA(S)
Function cooling heating
Capacity KW 8.0(2.1-9.8) 9.0(2.2-10)
Sensible heat ratio 0.74 /
Total power input KW 2.648(0.5-4.2) 2.631(0.5-4.2)
Max. power input W
4200 4200
EER or COP W/W 3.21 3.61
Dehumidifying capacity 10
-
³×m³/h 2.9
Power cable H05RN-F 4G 6.0mm
2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 10.8(2.3-14.3)/14.3 10.5(2.3-14.3)/14.3
Start Current A 3
Indoor
unit
Unit model (color) AD28MS2ERA(S)(D)
Fan
Type × Number CENTRIFUGALX2
Speed(H-M-L) r/min 1103/1014/978
Fan motor output/ input power W 185/320
Air-ow(H-M-L) m³/h 1630/1488/1421
External static pressure Pa 50/100
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 3
Total Area /
Dimension
External(L×W×H) mm×mm×mm 1135/742/270
Package(L×W×H) mm×mm×mm 1300/850/380
Drainage pipe (material , I.D./O.D.) mm PVC 35/39
Controller (O-Optional,S-Standard) Wired YR-E17(S) OR YR-E16A(O)
Fresh air hole dimension mm 200
Electricity Heater kW NONE
Sound power level (H-M-L) dB(A)
Sound pressure level (H-M-L) dB(A) 48/46/42
Piping
Type / Charge
g R410A/2000
Recharge quantity
g/m 45
Pipe
Liquid Pipe(mm)
mm 9.52
Gas Pipe(mm)
mm 15.88
Between I.D
&O.D
MAX.Drop
m 15
MAX.Piping length
m 25
Weight (Net / Shipping) kg / kg 45.4/51.3
Cooling Pdesignc(kW)
8KW SEER/CLASS 5.1/A QCE(Annual electricity consumption for cooling)kWh
555
Heating
Average Pdesignh(-10
) 7.4KW SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating)kWh
2745
Warmer Pdesignh(2
) 8.3 SCOP/CLASS 5.0/A++ QHE(Annual electricity consumption for heating)kWh
2509
Colder Pdesignh(-22
) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh
/
Tdesignh
-10
Tbivalent
-10
TOL
-15
Elbu:0
Max. cooling
condition
Indoor temperature: 32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature: 46
/-
Outdoor temperature
24
/18
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a