228
Super Match
Item Model 1U60IS1EAB(S)
Power cable H07RN-F 5G 4.0mm2
Connecting cable(including communication table H05RN-F 4G 2.5mm2
Power source N, V, Hz 3N~,380
400, 50Hz
Start Current A 62.5
Outdoor
unit
Unit model (color) 1U60IS1EAB(S)
WHITE
Compressor
Model / Manufacture/place JT170G-P8Y1(XI AN Daikin
Oil model FV50S
Oil charging 1500CM3
Type SCROLL
Fan
Type × Number axial×2
Speed r/min 850±40
Fan motor input power kW 0.130×2
Fan motor output power kW 0.070×2
Air-ow(H-M-L) m³/h 6500
Heat
exchanger
Type / Diameter mm TP2M/Φ7.94
Row/Fin pitch 2 1.5
Total area 1.17
Dimension
External
L×W×H
mm×mm×mm 948×340×1250
Package
L×W×H
mm×mm×mm 1095×410×1400
Drainage pipe (material , I.D./O.D.) mm /
Refrigerant control method mm/mm Electronic Expansion Valve 3.0MM
Defrosting auto
Volume of Accumulator L 4.0
Noise level dB(A) 60
Type of four way valve SHF-20A-46
material of reduce noise XPE
crankcase heater power W 38
Weight(Net / Shipping) kg / kg 108/118
Piping
Refrigerant
Type / Charge g R410A/3700
Maximum pipe length without
recharge refrigerant
m 5
Recharge quantity g/m 45
Pipe
Liquid mm 9.52
Gas mm 19.05
Connecting Method ared
Between I.D
&O.D
MAX.Drop m 30
MAX.Piping length m 50
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level.