EasyManua.ls Logo

Haier AC18CS1ERA - Page 405

Haier AC18CS1ERA
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electic Control and
Debugging
403
Super Match
Module input over-current
Correct the wiring due to diagram
Check if wire of electric box is
correct, and if compressor wire
is xed well
If compressor is
normal(compressor coil
resistor, insulation)
If power module is normal
Repalce compressor
Replace power module
Y
Y
Y
N
N
N
Solve the failures due
to relative information
MCU reset
Correct the wiring due to diagram
Check if wire of electric box
is correct , and if compressor
wire is xed well
If compressor is
normal(compressor coil
resistor, insulation)
If PCB is normal
Repalce compressor
Replace PCB
Y
Y
Y
N
N
Solve the failures due
to relative information
N