136
Comb.
Combinations
Rated
capacity(kW)
(Nom. cooling)
Total cooling
capacity(kW)
Total power input
(kW)
Total current
(A)@230V
EER
(W/W)
ENERGY
LABEL
SEER
(W/W)
ENERGY
LABEL
REMARKS
Unit
A
Unit
B
Unit
C
Unit
A
Unit
B
Unit
C
Min.
data
Rated
data
Max.
data
Min.
data
Rated
data
Nax.
data
Min.
data
Rated
data
Max.
data
Rated
capacity
1x1
2.0 2.00 0.80 2.00 2.80 0.55 0.62 1.30 2.44 2.75 5.8 3.23 A 6.40 A++
not
available
2.5 2.60 0.80 2.60 3.90 0.55 0.79 1.34 2.44 3.50 5.9 3.29 A 6.40 A++
not
available
3.5 3.60 1.00 3.60 5.30 0.55 1.09 1.65 2.44 4.84 7.3 3.30 A 6.40 A++
not
available
4.2 4.40 1.30 4.40 5.00 0.55 1.32 1.90 2.44 5.86 8.43 3.33 A 6.40 A++
not
available
5.0 5.20 1.40 5.20 7.00 0.55 1.55 2.00 2.44 6.88 8.9 3.35 A 6.40 A++
not
available
7.1 6.50 1.50 6.50 7.40 0.55 1.92 2.60 2.44 8.52 11.5 3.39 A 6.40 A++
not
available
BI
(1x2)
2.0 2.0 2.00 2.00 1.80 4.00 5.60 0.55 1.21 2.60 2.44 5.37 11.5 3.31 A 6.60 A++ available
2.0 2.5 2.00 2.60 1.80 4.60 6.70 0.55 1.35 2.64 2.44 5.99 11.7 3.41 A 6.60 A++ available
2.0 3.5 2.00 3.60 1.80 5.60 7.50 0.55 1.65 2.95 2.44 7.32 13.1 3.39 A 6.60 A++ available
2.0 4.2 2.00 4.40 1.80 6.40 7.60 0.55 1.89 3.00 2.44 8.39 13.3 3.39 A 6.70 A++
not
available
2.0 5.0 1.94 5.06 2.40 7.00 7.60 0.55 2.02 3.00 2.44 8.96 13.3 3.47 A 6.70 A++ available
2.5 2.5 2.60 2.60 2.00 5.20 7.40 0.55 1.52 2.68 2.44 6.74 11.9 3.42 A 6.70 A++ available
2.5 3.5 2.60 3.60 2.00 6.20 7.60 0.55 1.79 2.99 2.44 7.94 13.3 3.46 A 6.70 A++ available
2.5 4.2 2.60 4.40 2.40 7.00 7.60 0.55 2.02 3.00 2.44 8.96 13.3 3.47 A 6.70 A++
not
available
2.5 5.0 2.33 4.67 2.40 7.00 7.60 0.55 2.00 3.00 2.44 8.87 13.3 3.50 A 6.70 A++ available
3.5 3.5 3.40 3.40 2.40 6.80 7.60 0.55 2.00 3.20
2.44 8.87 14.2 3.40 A 6.20 A++ available
3.5 4.2 3.15 3.85 2.40 7.00 7.60 0.55 1.82 3.20 2.44 8.07 14.2 3.85 A 6.80 A++
not
available
3.5 5.0 2.86 4.14 2.40 7.00 7.60 0.55 1.82 3.20 2.44 8.07 14.2 3.85 A 6.80 A++ available
4.2 4.2 3.50 3.50 2.40 7.00 7.60 0.55 1.82 3.20 2.44 8.07 14.2 3.85 A 6.80 A++
not
available
TRI
(1x3)
2.0 2.0 2.0 2.00 2.00 2.00 2.40 6.00 7.60 0.55 1.75 2.70 2.44 7.76 12.0 3.43 A 7.20 A++ available
2.0 2.0 2.5 2.00 2.00 2.60 2.40 6.60 7.60 0.55 1.75 2.70 2.44 7.76 12.0 3.77 A 7.20 A++ available
2.0 2.0 3.5 1.84 1.84 3.32 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.20 A++ available
2.0 2.0 4.2 1.67 1.67 3.67 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.20 A++
not
available
2.0 2.0 5.0 1.52 1.52 3.96 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.20 A++ available
2.0 2.5 2.5 1.94 2.53 2.53 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.30 A++ available
2.0 2.5 3.5 1.71 2.22 3.07 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.30 A++ available
2.0 2.5 4.2 1.56 2.02 3.42 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.30 A++
not
available
2.0 2.5 5.0 1.43 1.86 3.71 2.40 7.00 7.60 0.55 1.82 2.70 2.44 8.07 12.0 3.85 A 7.30 A++ available
2.0 3.5 3.5 1.52 2.74 2.74 2.40 7.00 7.60 0.55 1.82 2.70 2.44 8.07 12.0 3.85 A 7.40 A++ available
2.0 3.5 4.2 1.40 2.52 3.08 2.40 7.00 7.60 0.55 1.80 2.70 2.44 7.99 12.0 3.89 A 7.40 A++
not
available
2.5 2.5 2.5 2.33 2.33 2.33 2.40 7.00 7.60 0.55 1.76 2.70 2.44 7.81 12.0 3.98 A 7.50 A++ available
2.5 2.5 3.5 2.07 2.07 2.86 2.40 7.00 7.60 0.55 1.78 2.70 2.44 7.90 12.0 3.93 A 7.50 A++ available
2.5 2.5 4.2 1.90 1.90 3.21 2.40 7.00 7.60 0.55 1.78 2.70 2.44 7.90 12.0 3.93 A 7.50 A++
not
available
2.5 3.5 3.5 1.86 2.57 2.57 2.40 7.00 7.60 0.55 1.78 2.70 2.44 7.90 12.0 3.93 A 7.50 A++ available